loading

Yunhan Global -Professional of Cardiovascular Medical Devices & Wearable ECG Monitor Provider.

Cynapse Intraoperative Neuromonitoring System (IONM) Real-Time 1
Cynapse Intraoperative Neuromonitoring System (IONM) Real-Time 2
Cynapse Intraoperative Neuromonitoring System (IONM) Real-Time 3
Cynapse Intraoperative Neuromonitoring System (IONM) Real-Time 4
Cynapse Intraoperative Neuromonitoring System (IONM) Real-Time 5
Cynapse Intraoperative Neuromonitoring System (IONM) Real-Time 6
Cynapse Intraoperative Neuromonitoring System (IONM) Real-Time 7
Cynapse Intraoperative Neuromonitoring System (IONM) Real-Time 1
Cynapse Intraoperative Neuromonitoring System (IONM) Real-Time 2
Cynapse Intraoperative Neuromonitoring System (IONM) Real-Time 3
Cynapse Intraoperative Neuromonitoring System (IONM) Real-Time 4
Cynapse Intraoperative Neuromonitoring System (IONM) Real-Time 5
Cynapse Intraoperative Neuromonitoring System (IONM) Real-Time 6
Cynapse Intraoperative Neuromonitoring System (IONM) Real-Time 7

Cynapse Intraoperative Neuromonitoring System (IONM) Real-Time

Recording multiple modules such as SEP, MEP, EMG, VEP, BAEP, EEG, etc., from the nervous system during operations to detect any adverse changes and enable corrective action.
5.0
design customization

    oops...!

    no product data.

    Go to homepage

    Description

    ● High-Capacity & Flexible I/O: Features a 16/32-channel amplifier, supplemented by 1 extra low-current stimulation port and a 9-channel stimulation box to handle complex monitoring scenarios.

    Comprehensive Modality Library: Supports over 16 flexible measurement modalities—including EMG, MEP, SEP, BAEP, VEP, and TOF—to meet the diverse needs of spinal, neurosurgical, and ENT procedures.

    Integrated & Robust Consumables: Utilizes a proprietary suite of integrated consumables, engineered for superior anti-interference capability to ensure waveform clarity and accuracy in the demanding OR environment.

    Streamlined Operational Workflow: The all-in-one consumables system and intuitive interface are designed to reduce setup time and simplify intraoperative procedures, enhancing overall efficiency.

    B-1 (2)

    Product parameters

    Measurement range 20μV-70000μV, with an error tolerance of ≤±10%
    CMRR ≥120 dB
    Input impedance (DIFF) ≥200MΩ
    Noise voltage <2.0μV p-p (low cut 0.2Hz, high cut 200Hz)
    Input impedance (COM) ≥3000 MΩ
    Stimulation frequency 0.01Hz-100Hz, error ≤±10%
    Pulse width 25μs-1000 μs, error ≤±10%
    Pulse width 25μs-1000 μs, error ≤±10%

    Advantages 

    Cynapse Intraoperative Neuromonitoring System (IONM) Real-Time 9
    Unmatched Procedural Versatility in a Single Platform
    Market Challenge: Complex surgeries often require monitoring multiple neural pathways, necessitating the use of multiple, discrete devices or complex reconfiguration during procedures. This equipment fragmentation increases setup time, cost, and operational complexity, potentially compromising workflow efficiency.

    NCC Solution (Comprehensive Modality Integration): The Cynapse IONM system integrates a full suite of monitoring capabilities within a single platform. With support for over 16 modalities—including EMG, MEP, SEP, BAEP, VEP, and TOF—and a high-capacity 16/32-channel amplifier with dedicated stimulation ports, it is engineered to meet the diverse requirements of spinal, neurosurgical, and ENT procedures without the need for multiple specialized systems.
    Cynapse Intraoperative Neuromonitoring System (IONM) Real-Time 10
    Uncompromised Signal Integrity for Confident Interpretation
    Market Challenge: The operating room (OR) is an electrically hostile environment where electromagnetic interference from numerous equipment can distort neurophysiological signals, leading to ambiguous data and potentially unreliable clinical interpretations.

    NCC Solution (Superior Anti-Interference & Accuracy): The system is complemented by a suite of proprietary, integrated consumables, specifically engineered with robust anti-interference capability. This design ensures the acquisition of high-fidelity, low-noise waveforms, providing a reliable foundation for precise and confident intraoperative decision-making.
    undefined
    Streamlined Workflow for Enhanced Operational Efficiency
    Market Challenge: Time-consuming setup, cable management, and intraoperative adjustments with non-integrated systems can prolong non-surgical time, increase the cognitive load on the monitoring team, and raise the risk of human error.

    NCC Solution (All-in-One Efficiency): The Cynapse IONM system addresses this through a highly streamlined workflow. The use of integrated consumables and an intuitive interface significantly reduces preparation time and simplifies intraoperative management. This allows the clinical team to focus on patient care and data interpretation rather than equipment troubleshooting, thereby improving overall procedural efficiency.

    Product display

    Cynapse Intraoperative Neuromonitoring System (IONM) Real-Time 12
    COMPANY STRENGTH
    Our in-house designers and engineers have produced countless great designs for customers from different industries
    Cynapse Intraoperative Neuromonitoring System (IONM) Real-Time 13
    COMPANY STRENGTH
    Our in-house designers and engineers have produced countless great designs for customers from different industries
    B-1 (2)
    B-1 (2)
    Newslatter
    Enter your email address to be the first to hear about new products and specials.
    Related Products
    Yuhan Global Limited is dedicated to advancing global cardiac health monitoring and telemedicine diagnostics, delivering reliable, accessible and innovative ECG solutions to improve healthcare access for patients around the world.
    Contact Us
    Contact person: susan
    Tel: +86 134 3712 3829
    WhatsApp: +86 134 3712 3829

    Add:
    Room a5,7/f, astoria building, no.34 ashley road, tsim sha tsui, hong kong
    Copyright © 2026 Yuhan Global Limited - www.yuhanglobal.com | SitemapPrivacy Policy
    Contact us
    whatsapp
    Contact customer service
    Contact us
    whatsapp
    cancel
    Customer service
    detect